Trade Price
£98.54
Per
1
Unit
EACH
Pack Quantity
Eaton Moeller series NZM - Molded Case Circuit Breaker. Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals
Product Length/Depth
115 mm
Product Height
65 mm
Product Width
75 mm
Product Weight
0.08 kg
Compliances
UL/CSA
IEC
RoHS conform
Certifications
CSA (Class No. 1437-01)
CSA (File No. 22086)
UL (File No. E140305)
UL listed
UL (Category Control Number DIHS)
CSA-C22.2 No. 5-09
UL489
CSA certified
CE marking
IEC60947
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Terminal capacity (solid cable)
0.2 mm² - 1.5 mm² (1x) for undervoltage release
0.2 mm² - 1.5 mm² (1x) at shunt release
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Minimum command time - min
10 ms
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Pick-up power consumption at AC (undervoltage release)
1.5 VA
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Rated control supply voltage (Us) at DC - min
24 V
Pick-up power consumption at DC (undervoltage release)
0.8 W
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
10.8 Connections for external conductors
Is the panel builder's responsibility.
Minimum command time - max
15 ms
Special features
Instantaneous shut-off of the NZM circuit breaker when the control voltage drops below 35 - 70% Us
For use with emergency-stop devices in connection with an emergency-stop button
For signalizing commands or different states of the circuit-breaker
Two relays per unit
The activation criteria can be configured in the trip unit
Configuration via communication, circuit breaker display, front USB port and Eaton Power Xpert Protection Manager
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on
Only for use with circuit-breakers with electronic trips
Under-voltage trip relay modules cannot be installed simultaneously with make-before-break auxiliary contact NZM...-XHIV, under-voltage trip NZM...-XU... or shunt trip NZM...-XA
Push-in clamp relay contacts for control wiring
Relays can be used for controlling remote operator with Us=208-204 V AC
Cannot be used with the PXR10 NZM-AX electronic trip
Rated control supply voltage (Us) at DC - max
24 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Used with
PXR20(25) NZM3(-4)-..X…
PXR20(25) NZM2(-4)-..X…
Electric connection type
Spring clamp connection
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Rated operational current
1 A (110 V AC-1, relay contacts)
1 A (230 V AC-1, relay contacts)
1 A (24 V DC-1, relay contacts)
1 A (24 V AC-1, relay contacts)
Number of contacts (normally closed contacts)
0
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Voltage type
DC
Drop-out voltage of undervoltage release AC/DC - min
0.35 x Us
Terminal capacity (stranded cable)
0.25 mm² - 1.5 mm² (1x) for undervoltage release
0.25 mm² - 1.5 mm² (1x) at shunt release
24 - 16 AWG (1x) at shunt release
24 - 16 AWG (1x) for undervoltage release
0.25 mm² - 0.75 mm² (1x) for undervoltage release
0.25 mm² - 0.75 mm² (1x) for undervoltage release with uninsulated end sleeve in accordance with DIN46228 / 1
0.25 mm² - 1.5 mm² (1x) for undervoltage release with insulated end sleeve in accordance with DIN46224 / 4
Frame
NZM2/3
Reaction time
19 ms
Suitable for
Motor safety switch
Off-load switch
Voltage tolerance - min
.85
Strip length
8 mm (relay contact connection)
Rated control voltage (relay contacts)
24 V AC
240 V AC
24 V DC
Power consumption
0.8 W (sealing DC)
1.5 VA (sealing AC)
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
Drop-out voltage of undervoltage release AC/DC - max
0.7 x Us
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Connection type
With push in terminal
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
II
Number of relays
2
Voltage tolerance - max
1.1
Undelayed short-circuit release - min
0 A
Pollution degree
2
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Rated impulse withstand voltage (Uimp)
4 kV AC
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (reference value) - min
0.1 mA / 0.1 VDC
Type
Accessory
Undervoltage release
Undervoltage release with two relays
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Number of contacts (normally open contacts)
2
Undelayed short-circuit release - max
0 A
Number of contacts (change-over contacts)
0
Rated insulation voltage (Ui)
250 V
Datasheet