NZMN1-AF80-NA

Circuit-breaker 3p fix settings

Trade Price

£408.76

Per

1

Unit

EACH

Pack Quantity

NZMN1-AF80-NA
NZMN1-AF80-NA
NZMN1-AF80-NA

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Circuit-breaker, 3p, 80A, N1-AF80-NA

Technical Specifications

Product Length/Depth

88 mm

Product Height

165.5 mm

Product Width

90 mm

Product Weight

1.065 kg

Compliances

RoHS conform

Certifications

UL (Category Control Number DIVQ)

CSA certified

IEC/EN 60947

CSA (File No. 22086)

CSA-C22.2 No. 5-09

UL listed

IEC 60947-2

CE marking

IEC

Specially designed for North America

UL/CSA

UL (File No. E31593)

UL 489

CSA (Class No. 1432-01)

Voltage rating

690 V - 690 V

Rated operating voltage Ue (UL) - max

480 Y / 277 V

Rated impulse withstand voltage (Uimp) at auxiliary contacts

6000 V

Rated impulse withstand voltage (Uimp) at main contacts

6000 V

Rated operational current

160 A (380/400 V AC-1, making and breaking capacity)

80 A (690 V AC-1, making and breaking capacity)

125 A (415 V AC-1, making and breaking capacity)

80 A (660-690 V AC-3, making and breaking capacity)

Amperage Rating

80 A

Instantaneous current setting (Ii) - min

6 A

Instantaneous current setting (Ii) - max

10 A

Overload current setting (Ir) - min

80 A

Overload current setting (Ir) - max

80 A

Short delay current setting (Isd) - min

0 A

Short delay current setting (Isd) - max

0 A

Short-circuit release non-delayed setting - min

480 A

Short-circuit release non-delayed setting - max

800 A

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz

85 kA

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz

50 kA

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz

35 kA

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz

10 kA

Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz

7.5 kA

Rated short-circuit making capacity Icm at 240 V, 50/60 Hz

187 kA

Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz

105 kA

Rated short-circuit making capacity Icm at 440 V, 50/60 Hz

74 kA

Rated short-circuit making capacity Icm at 525 V, 50/60 Hz

40 kA

Rated short-circuit making capacity Icm at 690 V, 50/60 Hz

17 kA

Short-circuit total breaktime

< 10 ms

Low-voltage HBC fuse - max

200 A gG/gL

Electrical connection type of main circuit

Frame clamp

Isolation

300 V AC (between the auxiliary contacts)

500 V AC (between auxiliary contacts and main contacts)

Number of operations per hour - max

120

Handle type

Rocker lever

Utilization category

A (IEC/EN 60947-2)

Overvoltage category

III

Pollution degree

3

Lifespan, electrical

10000 operations at 400 V AC-1

7500 operations at 690 V AC-1

Direction of incoming supply

As required

Mounting Method

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Fixed

Degree of protection

IP20

IP20 (basic degree of protection, in the operating controls area)

Degree of protection (IP), front side

IP40 (with insulating surround)

IP66 (with door coupling rotary handle)

Degree of protection (terminations)

IP10 (tunnel terminal)

IP00 (terminations, phase isolator and strip terminal)

Protection against direct contact

Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110

Shock resistance

20 g (half-sinusoidal shock 20 ms)

Number of auxiliary contacts (change-over contacts)

0

Number of auxiliary contacts (normally closed contacts)

0

Number of auxiliary contacts (normally open contacts)

0

Position of connection for main current circuit

Front side

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Lifespan, mechanical

20000 operations

Document Links