NZM1-XHB-DAR-NA

Main switch assembly kit, +additional handle red, size 1, NA type

Trade Price

£300.10

Per

1

Unit

EACH

Pack Quantity

NZM1-XHB-DAR-NA

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Main switch assembly kit, +additional handle red, size 1, NA type

Technical Specifications

Product Length/Depth

380 mm

Product Height

100 mm

Product Width

140 mm

Product Weight

0.683 kg

Compliances

IEC

UL/CSA

RoHS conform

Certifications

CE marking

CSA (File No. 22086)

UL (Category Control Number DIHS)

UL (File No. E140305)

IEC60947

UL listed

CSA (Class No. 1437-01)

NFPA79

UL489

Specially designed for North America

CSA-C22.2 No. 5-09

CSA certified

UL508A

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM1

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Suitable for

Switch disconnector

Power circuit breaker

Emergency stop

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Locking facility

Can also be modified in I position

Lockable on the switch in the 0 position

With door interlock

Lockable on the 0 position on the handle using up to 3 padlocks

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Fitted with:

Add-on rotary handle on switch with "Deliberate Action" operation as per NFPA79 and UL508A Part 2

NZM1/2-XV4 shaft extension for mounting depth of 400 mm

Door coupling rotary handle with rotary drive

External warning plate/marking plate in German/English

Black and yellow lightning symbol

Extension shaft

Padlock

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Special features

External warning plate/designation label can be clipped on.

For enhanced busbar tag shroud on the incomer side, please order IP2X protection against contact with a finger.

Kit for use as a main switch

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Color

Red

Degree of protection / NEMA enclosure type

IP66

4X. 12

Features

Lockable

With red door coupling rotary handle for use of switch as emergency switching off device

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Type

Accessory

Main switch assembly kit

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

N(S)1(-4)

NZM1(-4)

PN1(-4)

Cover/door type

Door interlock not defeated in the locked OFF position.

Door interlock on OFF with max. 3 padlocks

With activated door interlock. Cannot be opened in ON, OFF, or TRIP. Can only be opened in RESET.

Door interlock can be modified such that it can be defeated from the outside using a screwdriver

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Document Links

Datasheet