NZM-XCM

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Shunt release, for capacitor unit

Technical Specifications

Product Length/Depth

100 mm

Product Height

114 mm

Product Width

74 mm

Product Weight

0.48 kg

Compliances

IEC

RoHS conform

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM1/2/3/4

Rated control supply voltage (Us) at AC, 50 Hz - min

230 V

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Suitable for

Off-load switch

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Voltage rating at AC

230 V AC

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Rated control supply voltage (Us) at DC - min

0 V

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

Rated control supply voltage (Us) at AC, 50 Hz - max

230 V

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Overvoltage category

III

Special features

Capacitor unit 230 V 50/60 Hz in conjunction with NZM...-XA208-250 AC/DC shunt release

Enclosure: degree of protection IP20

not UL/CSA approved

Enables the safe use of circuit-breakers as mesh network circuit-breakers in the range from 0 – 110 % Un with constant switch-off time of 40 ms.

If the mains voltage is absent, the installed capacitor supplies power for actuating the shunt release for at least 12 hours.

The configuration of the capacitor unit is undertaken independently of the circuit-breaker.

Connect capacitor unit to the supply side!

Engineering Guidelines: Connect a standard auxiliary contact as N/O in series with the shunt release!

Standard auxiliary contact not included as standard.

Rated operation current (Ie)

< 10 mA

3 A

Undelayed short-circuit release - min

0 A

Pollution degree

3

Rated control supply voltage (Us) at AC, 60 Hz - min

230 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Terminal capacity (solid/flexible conductor)

20 - 14 AWG (1x) with ferrule

0.5 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule

0.5 mm² - 2.5 mm² (1x) at shunt release with ferrule

20 - 16 AWG (2x) with ferrule

Rated impulse withstand voltage of main contacts

8000 V

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Rated control supply voltage (Us) at DC - max

0 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Type

Accessory

Shunt release

Shunt release for capacitor unit

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Rated control supply voltage (Us) at AC, 60 Hz - max

230 V

Used with

NZM2(-4), N(S)2(-4)

NZM3(-4), N(S)3(-4)

NZM1(-4), N(S)1(-4)

NZM4(-4), N(S)4(-4)

Number of contacts (normally open contacts)

0

Undelayed short-circuit release - max

0 A

Electric connection type

Screw connection

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Rated impulse withstand voltage of auxiliary contacts

8000 V

Number of contacts (change-over contacts)

0

Voltage type

DC

Document Links