Eaton Moeller series NZM - Molded Case Circuit Breaker. Shunt release, for capacitor unit
Product Length/Depth
100 mm
Product Height
114 mm
Product Width
74 mm
Product Weight
0.48 kg
Compliances
IEC
RoHS conform
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Frame
NZM1/2/3/4
Rated control supply voltage (Us) at AC, 50 Hz - min
230 V
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Suitable for
Off-load switch
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Voltage rating at AC
230 V AC
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Rated control supply voltage (Us) at DC - min
0 V
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
Rated control supply voltage (Us) at AC, 50 Hz - max
230 V
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Special features
Capacitor unit 230 V 50/60 Hz in conjunction with NZM...-XA208-250 AC/DC shunt release
Enclosure: degree of protection IP20
not UL/CSA approved
Enables the safe use of circuit-breakers as mesh network circuit-breakers in the range from 0 – 110 % Un with constant switch-off time of 40 ms.
If the mains voltage is absent, the installed capacitor supplies power for actuating the shunt release for at least 12 hours.
The configuration of the capacitor unit is undertaken independently of the circuit-breaker.
Connect capacitor unit to the supply side!
Engineering Guidelines: Connect a standard auxiliary contact as N/O in series with the shunt release!
Standard auxiliary contact not included as standard.
Rated operation current (Ie)
< 10 mA
3 A
Undelayed short-circuit release - min
0 A
Pollution degree
3
Rated control supply voltage (Us) at AC, 60 Hz - min
230 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Terminal capacity (solid/flexible conductor)
20 - 14 AWG (1x) with ferrule
0.5 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.5 mm² - 2.5 mm² (1x) at shunt release with ferrule
20 - 16 AWG (2x) with ferrule
Rated impulse withstand voltage of main contacts
8000 V
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated control supply voltage (Us) at DC - max
0 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Type
Accessory
Shunt release
Shunt release for capacitor unit
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage (Us) at AC, 60 Hz - max
230 V
Used with
NZM2(-4), N(S)2(-4)
NZM3(-4), N(S)3(-4)
NZM1(-4), N(S)1(-4)
NZM4(-4), N(S)4(-4)
Number of contacts (normally open contacts)
0
Undelayed short-circuit release - max
0 A
Electric connection type
Screw connection
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Number of contacts (normally closed contacts)
0
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Rated impulse withstand voltage of auxiliary contacts
8000 V
Number of contacts (change-over contacts)
0
Voltage type
DC
Datasheet