LRD166

OVERLOAD REL.9 A 13A CF

Trade Price

£57.98

Per

1

Unit

EA

Pack Quantity

1

LRD166

Information

TeSys LRD thermal overload relay, 13A/690V, thermal setting range 9-13A, tripping class 10A, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D12-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Technical Specifications

Range

TeSys TeSys Deca

Product name

TeSys LRD TeSys Deca

Product or component type

Differential thermal overload relay

Device short name

LRD

Relay application

Motor protection

Product compatibility

LC1D38 LC1D18 LC1D25 LC1D32 LC1D12

Network type

DC AC

Thermal overload class

Class 10A conforming to IEC 60947-4-1

Thermal protection adjustment range

9…13 A

[Ui] rated insulation voltage

Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1

Network frequency

0...400 Hz

Mounting support

Plate, with specific accessories Rail, with specific accessories Under contactor

Tripping threshold

1.14 +/- 0.06 Ir conforming to IEC 60947-4-1

Auxiliary contact composition

1 NO + 1 NC

[Ith] conventional free air thermal current

5 A for signalling circuit

Permissible current

3 A at 120 V AC-15 for signalling circuit 0.22 A at 125 V DC-13 for signalling circuit

[Ue] rated operational voltage

690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1

Associated fuse rating

4 A gG for signalling circuit 4 A BS for signalling circuit

[Uimp] rated impulse withstand voltage

6 kV

Phase failure sensitivity

Tripping current 130 % of Ir on two phase, the last one at 0

Control type

Red push-button: stop Blue push-button: reset

Temperature compensation

-20…60 °C

Connection pitch

14.5 mm

Connections - terminals

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end Power circuit: lugs-ring terminals

Tightening torque

Control circuit: 1.7 N.m - on screw clamp terminals Power circuit: 2.3 N.m - on lugs-ring terminals M4

height

66 mm

Width

45 mm

Depth

70 mm

Net weight

0.124 kg

Climatic withstand

conforming to IACS E10

IP degree of protection

IP20 conforming to IEC 60529

Ambient air temperature for operation

-20…60 °C without derating conforming to IEC 60947-4-1

Ambient air temperature for storage

-60…70 °C

Flame retardance

V1 conforming to UL 94

Mechanical robustness

Vibrations: 6 Gn conforming to IEC 60068-2-6 Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7

Dielectric strength

1.89 kV at 50 Hz conforming to IEC 60947-1

standards

EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495

product certifications

IEC UL CSA CCC EAC BV RINA DNV-GL LROS (Lloyds register of shipping) ATEX INERIS UKCA

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

8.800 cm

Package 1 Width

7.700 cm

Package 1 Length

4.900 cm

Package 1 Weight

148.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

24

Package 2 Height

15.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

3.881 kg

Warranty

18 months

Document Links

Datasheet