Information

Low voltage power factor correction solution, from VarSet family, helps to eliminate utility penalties. To do energy savings, to lower capital costs, and to reduce CO² emissions by the reactive power compensation of inductive loads. This hardware is compatible with power management software to take advantage of the IoT digital power installation and allow a seemless integration to EcoStruxture Power. Smart monitoring and measurement features are available to secure operations. To optimize perfomance and maintenance, across a broad range of applications, commercial or industrial. This capacitor bank version, suitable for network voltage 400 to 415V 50Hz is providing a reactive power up to 275kvar. The compensation is automatically adjusted by the Power factor controller from VarplusLogic family. It is designed for network harmonic voltage up to 4% or network harmonic current up to 10%, network defined as a low polluted harmonic network. VarSet range is certified to CE, IEC 61921, IEC 61439 part 1 & IEC61439 part 2. It is embedding high life expectancy capacitors from Varplus family designed as per IEC831 part 1 and IEC831 part 2. And include a smart controller with modbus communication RS485. The enclosure RAL7035 is a wall-mounted type with a bottom entry incoming connection. Frame exterior dimensions are 1000 millimetres in width, 300 millimetres in depth, 1200 millimetres height and a max product weight of 175kg. As a standard, the enclosures are IP31. Optionnal kits are available to transform them easily into a IP54. This product is particularly adapted for power factor correction applications with variable or unstable loads.

Technical Specifications

Network rated voltage

400 V AC 50 Hz 415 V AC 50 Hz

Reactive power rating

275 kvar

Operating mode

Automatic

Range

PowerLogic

Device short name

automatic capacitor bank

Product or component type

Capacitor bank

Network pollution level

Low polluted

[Gh/Sn] harmonic pollution rate

15…25 %

[THDU] total harmonic distorsion of voltage

3…4 %

Power per step

25 kvar

Step composition

25 + 5x50

Location of connection

Bottom

Controller type

PowerLogic PFC Controller VPL6

capacitor technology

PowerLogic PFC Capacitor

Poles description

3P

capacitance tolerance

- 5 % to 10 %

[Ui] rated insulation voltage

690 V

[Uimp] rated impulse withstand voltage

8 kV

Maximum permissible voltage

1.1 x Un (8 hours over 24 hours) conforming to IEC 60831

[Imp] maximum permanent current

Capacitor: 1.8 x In at 480 V conforming to IEC 60831 Battery: 1.43 x In at 400 V conforming to IEC 61439-2 Battery: 1.19 x In at 415 V conforming to IEC 61439-2

main incomer protection

Without protection

[Icw] rated short-time withstand current

30 kA at 1 s (Icw)

Step protection type

Overload: harmonic control from PowerLogic PFC Controller Short-circuit: upstream protection

accessibility for operation

Front

Colour

Grey (RAL 7035)

maximum weight

175 kg

height

1200 mm

Width

1000 mm

Depth

300 mm

Provided equipment

Auxiliary transformer

Internal voltage transformer

400/230 V - 400 VA

Function available

GenSet shedding contact Alarm contact

standards

IEC 61921 IEC 61439-2 IEC 61439-1

product certifications

CE ASEFA EAC

Mounting location

Indoor

IP degree of protection

Environment: IP31 Safety: IPxx B

IK degree of protection

IK10

Relative humidity

0…95 %

Operating altitude

<= 2000 m

Ambient air temperature for operation

-5…45 °C

Average ambient air temperature for operation

35 °C (annual) 45 °C (over 24 hours)

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

134.0 cm

Package 1 Width

80.0 cm

Package 1 Length

120.0 cm

Package 1 Weight

154.0 kg

Warranty

18 months

Document Links