Trade Price
POA
Per
1
Unit
EA
Pack Quantity
1
Low voltage power factor correction solution, from VarSet family, helps to eliminate utility penalties. To do energy savings, to lower capital costs, and to reduce CO² emissions by the reactive power compensation of inductive loads. This hardware is compatible with power management software to take advantage of the IoT digital power installation and allow a seemless integration to EcoStruxture Power. Smart monitoring and measurement features are available to secure operations. To optimize perfomance and maintenance, across a broad range of applications, commercial or industrial. This capacitor bank version, suitable for network voltage 400 to 415V 50Hz is providing a reactive power up to 200kvar. The compensation is automatically adjusted by the Power factor controller from VarplusLogic family. It is designed for network harmonic voltage up to 4% or network harmonic current up to 10%, network defined as a low polluted harmonic network. VarSet range is certified to CE, IEC 61921, IEC 61439 part 1 & IEC61439 part 2. It is embedding high life expectancy capacitors from Varplus family designed as per IEC831 part 1 and IEC831 part 2. And include a smart controller with modbus communication RS485. The enclosure RAL7035 is a wall-mounted type with a bottom entry incoming connection. Frame exterior dimensions are 1000 millimetres in width, 300 millimetres in depth, 1200 millimetres height and a max product weight of 175kg. As a standard, the enclosures are IP31. Optionnal kits are available to transform them easily into a IP54. This product is particularly adapted for power factor correction applications with variable or unstable loads.
Network rated voltage
400 V AC 50 Hz 415 V AC 50 Hz
Reactive power rating
200 kvar
Operating mode
Automatic
Range
PowerLogic
Device short name
automatic capacitor bank
Product or component type
Capacitor bank
Network pollution level
Low polluted
[Gh/Sn] harmonic pollution rate
15…25 %
[THDU] total harmonic distorsion of voltage
3…4 %
Power per step
25 kvar
Step composition
25 + 25 + 3x50
Location of connection
Bottom
Controller type
PowerLogic PFC Controller VPL6
capacitor technology
PowerLogic PFC Capacitor
Poles description
3P
capacitance tolerance
- 5 % to 10 %
[Ui] rated insulation voltage
690 V
[Uimp] rated impulse withstand voltage
8 kV
Maximum permissible voltage
1.1 x Un (8 hours over 24 hours) conforming to IEC 60831
[Imp] maximum permanent current
Capacitor: 1.8 x In at 480 V conforming to IEC 60831 Battery: 1.43 x In at 400 V conforming to IEC 61439-2 Battery: 1.19 x In at 415 V conforming to IEC 61439-2
main incomer protection
Without protection
[Icw] rated short-time withstand current
30 kA at 1 s (Icw)
Step protection type
Overload: harmonic control from PowerLogic PFC Controller Short-circuit: upstream protection
accessibility for operation
Front
Colour
Grey (RAL 7035)
maximum weight
175 kg
height
1200 mm
Width
1000 mm
Depth
300 mm
Provided equipment
Auxiliary transformer
Internal voltage transformer
400/230 V - 400 VA
Function available
GenSet shedding contact Alarm contact
standards
IEC 61439-1 IEC 61921 IEC 61439-2
product certifications
ASEFA EAC CE
Mounting location
Indoor
IP degree of protection
Environment: IP31 Safety: IPxx B
IK degree of protection
IK10
Relative humidity
0…95 %
Operating altitude
<= 2000 m
Ambient air temperature for operation
-5…45 °C
Average ambient air temperature for operation
35 °C (annual) 45 °C (over 24 hours)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
134.000 cm
Package 1 Width
80.000 cm
Package 1 Length
120.000 cm
Package 1 Weight
141.000 kg
Warranty
18 months
Datasheet