Trade Price
£39,790.82
Per
1
Unit
EA
Pack Quantity
1
Low voltage power factor correction solution, from VarSet family, helps to eliminate utility penalties. To do energy savings, to lower capital costs, and to reduce CO² emissions by the reactive power compensation of inductive loads. This hardware is compatible with power management software to take advantage of the IoT digital power installation and allow a seemless integration to EcoStruxture Power. Smart monitoring and measurement features are available to secure operations. To optimize perfomance and maintenance, across a broad range of applications, commercial or industrial. This capacitor bank version, suitable for network voltage 400 to 415V 50Hz is providing a reactive power up to 600kvar with a tuning frequency of 190Hz. The compensation is automatically adjusted by the Power factor controller from VarplusLogic family. It is designed for network harmonic voltage up to 7% or network harmonic current up to 20%, network defined as a polluted harmonic network. VarSet range is certified to CE, IEC 61921, IEC 61439 part 1 & IEC61439 part 2. It is embedding high life expectancy capacitors from Varplus family designed as per IEC831 part 1 and IEC831 part 2. And include a smart controller with modbus communication RS485. The enclosure RAL7035 is a floor standing type with a top entry incoming connection protected by a circuit breaker. Frame exterior dimensions are 1400 millimetres in width, 600 millimetres in depth, 2200 millimetres height and a max product weight of 952kg. As a standard, the enclosures are IP31. Optionnal kits are available to transform them easily into a IP54. This product is particularly adapted for power factor correction applications with variable or unstable loads.
Network rated voltage
400 V AC 50 Hz 415 V AC 50 Hz
Reactive power rating
600 kvar
Operating mode
Automatic
Range
PowerLogic
Device short name
automatic capacitor bank with detuned reactor
Product or component type
Capacitor bank
Network pollution level
Polluted
[Gh/Sn] harmonic pollution rate
25…50 %
[THDU] total harmonic distorsion of voltage
4…7 %
Tuning factor
3.8
Tuning frequency
190 Hz
Power per step
100 kvar
Step composition
6x100
Location of connection
Top
Controller type
PowerLogic PFC Controller VPL6
capacitor technology
PowerLogic PFC Capacitor + Detuned Reactor
Poles description
3P
capacitance tolerance
- 5 % to 10 %
[Ui] rated insulation voltage
800 V
[Uimp] rated impulse withstand voltage
8 kV
Maximum permissible voltage
1.1 x Un (8 hours over 24 hours) conforming to IEC 60831
[Imp] maximum permanent current
Capacitor: 1.8 x In at 480 V conforming to IEC 60831 Battery: 1.19 x In at 400 V conforming to IEC 61439-2 Battery: 1.19 x In at 415 V conforming to IEC 61439-2
main incomer protection
Circuit breaker protection
Breaking capacity
Icu 50 kA
Control type
Rotary handle
Step protection type
Overload: harmonic control from PowerLogic PFC Controller Short-circuit: fuse
accessibility for operation
Front
Colour
Grey (RAL 7035)
maximum weight
952 kg
height
2200 mm
Width
800 mm capacitor: 600 mm detuned reactor:
Depth
600 mm
Provided equipment
Auxiliary transformer
Internal voltage transformer
400/230 V - 1000 VA
Function available
Alarm contact GenSet shedding contact
standards
IEC 61439-2 IEC 61439-1 IEC 61921
product certifications
EAC ASEFA CE
Mounting location
Indoor
IP degree of protection
Environment: IP31 Safety: IPxx B
IK degree of protection
IK10
Relative humidity
0…95 %
Operating altitude
<= 2000 m
Ambient air temperature for operation
-5…45 °C
Average ambient air temperature for operation
35 °C (annual) 45 °C (over 24 hours)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
230.0 cm
Package 1 Width
80.0 cm
Package 1 Length
156.0 cm
Package 1 Weight
986.0 kg
Warranty
18 months
Datasheet