ATS480M12Y

SoftStarterATS480 1200A 208to690V

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

ATS480M12Y

Information

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 1200A in normal duty, it supplies motor from 355kW to 900kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 770mm (width) x 329mm (depth) x 890mm (height) and it weighs 115kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus… The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems. It is a Green Premium product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Technical Specifications

Range of product

Altivar Soft Starter ATS480

Product or component type

Soft starter

Product destination

Asynchronous motors

Product specific application

Process and infrastructures

Device short name

ATS480

Network number of phases

3 phases

utilisation category

AC-3A AC-53A

Ue power supply voltage

208...690 V - 15...10 %

power supply frequency

50...60 Hz - 20...20 %

[Ie] rated operational current

Normal duty: 1200.0 A (at <40 °C)

rated current in heavy duty

1045.0 A at 40 °C for heavy duty

Torque control

True

IP degree of protection

IP00

Motor power kW

355.0 kW at 230 V in the motor supply line normal duty 250.0 kW at 230 V in the motor supply line heavy duty 630.0 kW at 400 V in the motor supply line normal duty 500.0 kW at 400 V in the motor supply line heavy duty 710.0 kW at 440 V in the motor supply line normal duty 630.0 kW at 440 V in the motor supply line heavy duty 800.0 kW at 500 V in the motor supply line normal duty 630.0 kW at 500 V in the motor supply line heavy duty 800.0 kW at 525 V in the motor supply line normal duty 630.0 kW at 525 V in the motor supply line heavy duty 900.0 kW at 660 V in the motor supply line heavy duty 900.0 kW at 690 V in the motor supply line heavy duty 500.0 kW at 230 V to the motor delta terminals normal duty 710.0 kW at 400 V to the motor delta terminals heavy duty

Motor power hp

400.0 hp at 208 V normal duty 350.0 hp at 208 V heavy duty 450.0 hp at 230 V normal duty 350.0 hp at 230 V heavy duty 1000.0 hp at 460 V normal duty 800.0 hp at 460 V heavy duty 1200.0 hp at 575 V normal duty 1000.0 hp at 575 V heavy duty

Option card

Communication module for Profibus DP V1 Communication module for PROFINET Communication module for Modbus TCP/EtherNet/IP Communication module for CANopen daisy chain Communication module for CANopen Sub-D Communication module for CANopen open style

device connection

In the motor supply line To the motor delta terminals

[Us] control circuit voltage

110...250 V AC 50/60 Hz - 15...10 %

Apparent power

0.2 kVA

Integrated motor overload protection

True

motor thermal protection class

Class 10E

Protection type

Phase failure: line Integrated thermal protection: motor Thermal protection: starter Current overload: motor Underload: motor Excessive starting time, locked rotor: motor Motor phase loss: motor Line supply phase loss: line Line supply phase loss: motor Thermal protection: motor

current limiting %In (5 x Ie maximum)

150…700 %

Rated current pwr loss specification

1200.0 A

Power loss static current independent

25.0 W

Power loss per device current dependent

3472.0 W

standards

IEC 60947-4-2 UL 60947-4-2 IEC 60664-1

product certifications

CE cULus CCC UKCA RCM EAC DNV ABS BV CCS

Marking

CE CCC UKCA EAC RCM CULus

[Uc] control circuit voltage

24 V DC

Discrete input number

4

Discrete input type

(STOP) logic inputs, 3500 Ohm (RUN) logic inputs, 3500 Ohm (DI3) programmable as logic input, 3500 Ohm (DI4) programmable as logic input, 3500 Ohm

Input compatibility

STOP: discrete input level 1 PLC conforming to IEC 61131-2 RUN: discrete input level 1 PLC conforming to IEC 61131-2 DI3: discrete input level 1 PLC conforming to IEC 61131-2 DI4: discrete input level 1 PLC conforming to IEC 61131-2

Discrete input logic

Programmable digital input at State 0: < 5 V

Relay output number

3

Relay output type

Relay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable

Minimum switching current

100 mA at 12 V DC for relay outputs

Maximum switching current

Relay outputs 2 A at 250 V AC Relay outputs 2 A at 30 V DC Relay outputs

Discrete output number

2

Discrete output type

(DQ1) programmable digital output <= 30 V (DQ2) programmable digital output <= 30 V

Output compatibility

Open collector level 1 PLC conforming to IEC 65A-68

analogue input number

1

Analogue input type

AI1/PTC PTC/Pt 100 temperature probe PTC2 PTC/Pt 100 temperature probe PTC3 PTC/Pt 100 temperature probe

analogue output number

1

Analogue output type

Current output AQ1: 0...20 mA or 0...10 V, impedance <500 Ohm

Communication port protocol

Modbus serial

Connector type

1 RJ45

Communication data link

Serial

Physical interface

2-wire RS 485

Transmission rate

1200...256000 bit/s

Transmission frame

RTU

Data format

8 bits, configurable odd, even or no parity

Type of polarization

No impedance for Modbus serial

Number of addresses

0…227 for Modbus serial

Method of access

Slave Modbus serial

Function available

External bypass control Pre-heating Smoke extraction Multi-motor cascade Second motor set User management Ports and services hardening Security event logging Cybersecure firmware update Single direction

Display screen available

True

Operating position

Vertical +/- 10 degree

height

890.0 mm

Width

770.0 mm

Depth

329.0 mm

Net weight

115.0 kg

Electromagnetic compatibility

Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-11 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5

Pollution degree

Level 3

[Uimp] rated impulse withstand voltage

6 kV

[Ui] rated insulation voltage

690 V

Environmental class (during operation)

Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3

Relative humidity

0…95 % without condensation or dripping water conforming to IEC 60068-2-3

Ambient air temperature for operation

40…60 °C (with current derating of 2 % per °C) -15…40 °C (without derating)

Ambient air temperature for storage

-25…70 °C

Operating altitude

<= 1000 m without derating > 1000...4000 m with current derating 1 % per 100 m

Maximum deflection under vibratory load (during operation)

1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during storage)

1.75 mm at 2...9 Hz

Maximum deflection under vibratory load (during transport)

1.75 mm at 2...9 Hz

Maximum acceleration under vibrational stress (during operation)

10 m/s² at 13...200 Hz

Maximum acceleration under vibratory load (during storage)

15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz

Maximum acceleration under vibratory load (during transport)

15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz

Maximum acceleration under shock impact (during operation)

150 m/s² at 11 ms

Maximum acceleration under shock load (during storage)

100 m/s² at 11 ms

Maximum acceleration under shock load (during transport)

100 m/s² at 11 ms

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

59.0 cm

Package 1 Width

95.0 cm

Package 1 Length

103.0 cm

Package 1 Weight

135.0 kg

Warranty

18 months

Document Links

Datasheet