ABLU3A48100

POWER SUPPLY 48V 10A 3PH UNI.

Trade Price

£409.50

Per

1

Unit

EA

Pack Quantity

1

ABLU3A48100

Technical Specifications

Range of product

Modicon Power Supply

Product or component type

Power supply

Power supply type

Regulated switch mode

Variant option

Universal

Enclosure material

Metal

Nominal input voltage

380...500 V AC three phase

Rated power in W

480 W

Output voltage

48 V DC

Power supply output current

10 A

Permissible temporary current boost

1.5 x In (for 5 seconds)

Input voltage limits

320...575 V AC 3 phases

Nominal network frequency

50…60 Hz

Network system compatibility

TN TT IT

Maximum leakage current

2 mA 500 V AC

Input protection type

Integrated fuse (not interchangeable) 3.15 A External protection (recommended)

Inrush current

35 A at 380 V 35 A at 500 V

Power factor

0.90 at 380 V AC 0.88 at 500 V AC

Efficiency

92 % at 380 V AC 92 % at 500 V AC

Output voltage adjustment

48…56 V

Power dissipation in W

33 W

Current consumption

< 0.85 A 380 V AC < 0.73 A 500 V AC

Turn-on time

< 1 s

Holding time

> 20 ms 380 V AC > 20 ms 500 V AC

Startup with capacitive loads

200000 µF

Residual ripple

< 150 mV

Meantime between failure [MTBF]

890200 h at 25 °C, full load conforming to SR 332 346200 h at 55 °C, 80 % load conforming to SR 332

Output protection type

Against overload and short-circuits, protection technology: manual or automatic reset by switch Against over temperature, protection technology: automatic reset Against overvoltage, protection technology: manual reset

Connections - terminals

Screw connection: 4...6 mm², (AWG 12...AWG 10) without wire end ferrule for output Screw connection: 4 mm², (AWG 12) with wire end ferrule for output Screw connection: 0.75…6 mm², (AWG 18...AWG 10) without wire end ferrule for input Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for diagnostic relay Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for diagnostic relay Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for shut down input

Line and load regulation

< 0.17 % at 100 % load in line at 25 °C < 0.6 % +/- 0.5 % at 150 % load at 25 °C

Status LED

1 LED (green and red) product status

Depth

127.2 mm

height

124 mm

Width

65 mm

Net weight

1.15 kg

Output coupling

Parallel

Marking

CE UKCA

Mounting support

Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail

Supply

SELV conforming to EN/IEC 60950-1 SELV conforming to EN/IEC 60204-1 SELV conforming to IEC 60364-4-41

Dielectric strength

4000 V AC with input to output 2000 V AC with input to ground 1500 V AC with output to ground 4000 V AC with input to diagnostic relay 500 V AC with output to diagnostic relay 1500 V AC with diagnostic relay to ground with shutdown input not isolated from output

Diagnostic relay

Electromechanical relay 1000.0 mA 30 V

Service life

10 year(s) 40 °C 80 % load

Overvoltage category

III II

standards

EN 62368-1 EN/IEC 61204-3 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 EN 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 CSA C22.2 No 107.1 EN/IEC 62368-1

Product certifications

CE CUL listed CUL recognized RCM CB Scheme EAC KC UKCA CURus

Operating altitude

< 5000 m overvoltage category III overvoltage category II

Shock resistance

150 m/s² for 11 ms

IP degree of protection

IP20

Ambient air temperature for operation

-25…55 °C without current derating mounting position A < 2000 m 55…70 °C with current derating of 3.3 % per °C mounting position A < 2000 m

Electrical shock protection class

Class I

Pollution degree

2

Vibration resistance

3.5 mm (f= 3…11.9 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 11.9…150 Hz) conforming to IEC 60068-2-6

Electromagnetic immunity

Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to EN/IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to EN/IEC 61000-4-2 Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to EN/IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to EN/IEC 61000-4-5 Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8 Immunity to voltage dips conforming to EN/IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to EN 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1

Electromagnetic emission

Conducted emissions conforming to EN 61000-6-3 Radiated emissions conforming to EN 61000-6-4

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.45 cm

Package 1 Width

17.7 cm

Package 1 Length

18.7 cm

Package 1 Weight

1.512 kg

Unit Type of Package 2

S03

Number of Units in Package 2

7

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

11.2 kg

Warranty

18 months

Document Links

Datasheet