This Acti9 iQuick PRD8r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 or Type 3 device autoprotected by integrated circuit-breaker is recommended for moderate risk level in secondary panel board. It offers remote reporting of the "cartridge must be changed" message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 25kA. This Acti9 iQuick PRD8r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 8kA. The In nominal discharge current is 2kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode is 264VAC between neutral and earth, and is 350VAC between phase and earth. The Up Voltage protection level in type 2 is 1.5kV in common mode (L/PE or N/PE), and is 1.2kV in differential mode (L/N). The Up Voltage protection level in type 3 is 1.4kV in common mode (L/PE), 1.5kV in common mode (N/PE), and 1.4kV in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 810g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 and IEC 61643-11: 2011 Type 2 standards.
range of product
Acti9
Product name
Acti9 iQuick PRD
Product or component type
Surge arrester with pluggable cartridge
Device short name
iQuick PRD8r
Device application
Distribution
Standards
EN 61643-11:2012 IEC 61643-11:2011
product certifications
CE
Quality labels
KEMA-KEUR NF
Poles description
3P + N
Remote signalling
With
Signal contacts composition
1 SD (1 C/O)
Surge arrester type
Electrical distribution network
Earthing system
TT TN-S
Surge arrester class type
Type 2 + 3
Surge arrester technology
MOV + GDT
[Ue] rated operational voltage
230/400 V AC (+/- 10 %) at 50/60 Hz
[In] nominal discharge current
Common mode: 2 kA (L/PE) Common mode: 2 kA (N/PE) Differential mode: 2 kA (L/N)
[Imax] maximum discharge current
Common mode: 8 kA L/PE Common mode: 8 kA N/PE Differential mode: 8 kA L/N
[Uoc] open circuit voltage
10 kV type 3 common mode L/PE 10 kV type 3 common mode N/PE 10 kV type 3 differential mode L/N
[Uc] maximum continuous operating voltage
Common mode: 264 V N/PE Common mode: 350 V L/PE Differential mode: 350 V L/N
Maximum [Up] voltage protection level
Common mode <1.5 kV type 2 L/PE Common mode <1.7 kV type 2 N/PE Differential mode <1.2 kV type 2 L/N Common mode <1.4 kV type 3 L/PE Differential mode <1.4 kV type 3 L/N Common mode <1.5 kV type 3 N/PE
Disconnector device type
Integrated circuit breaker - Icu 25 kA
Signalling circuit voltage
2 A/250 V AC 50/60 Hz
Mounting mode
Clip-on (DIN rail)
9 mm pitches
14.6
height
94 mm
Width
131.5 mm
Depth
75.9 mm
Net weight
0.84 kg
Colour
White (RAL 9003)
Connections - terminals
Tunnel type terminal (downside) 2.5…25 mm² Tunnel type terminal (upside) 2.5…25 mm²
Tightening torque
2.5 N.m
IK degree of protection
IK05 conforming to IEC 62262
Relative humidity
5…90 %
Operating altitude
2000 m
Ambient air temperature for operation
-25…60 °C
Ambient air temperature for storage
-40…70 °C
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
9.0 cm
Package 1 Width
10.0 cm
Package 1 Length
15.0 cm
Package 1 Weight
874.0 g
Unit Type of Package 2
S03
Number of Units in Package 2
12
Package 2 Height
30.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
11.083 kg
Warranty
18 months
Datasheet