Trade Price
POA
Per
1
Unit
EA
Pack Quantity
1
This Acti9 iPRD surge arrester protects 1P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 260VAC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and 1.6kV in differential mode (L/N) . The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 220g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.
range of product
Acti9
Product name
Acti9 iPRD
Product or component type
Surge arrester with pluggable cartridge
Device short name
iPRD40r
Device application
Distribution
Standards
EN 61643-11:2012 IEC 61643-11:2011
product certifications
CE
Quality labels
NF KEMA-KEUR
Poles description
1P + N
Remote signalling
With
Signal contacts composition
1 SD (1 C/O)
Surge arrester type
Electrical distribution network
Earthing system
TT TN-S
Surge arrester class type
Type 2
Surge arrester technology
MOV + GDT
[Ue] rated operational voltage
230/400 V AC (+/- 10 %) at 50/60 Hz
[In] nominal discharge current
Common mode: 15 kA (L/PE) Common mode: 15 kA (N/PE) Differential mode: 15 kA (L/N)
[Imax] maximum discharge current
Common mode: 40 kA L/PE Common mode: 40 kA N/PE Differential mode: 40 kA L/N
[Uc] maximum continuous operating voltage
Common mode: 260 V N/PE Differential mode: 350 V L/N
Maximum [Up] voltage protection level
Common mode <1.4 kV type 2 N/PE Differential mode <1.6 kV type 2 L/N
[Ut] temporary overvoltage
337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode 442 V L/PE 5 s withstand 1455 V L/PE 200 ms safe failure mode
Disconnector device type
Associated circuit breaker iC60H 40 A curve C - Icu 15 kA Associated circuit breaker IC60N 40 A curve C - Icu 10 kA Associated circuit breaker NG125H 40 A curve C - Icu 36 kA Associated circuit breaker NG125L 40 A curve C - Icu 50 kA Associated circuit breaker NG125N 40 A curve C - Icu 25 kA Associated fuse gG 63 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage
0.25 A/250 V AC 50/60 Hz
Mounting mode
Clip-on (DIN rail)
9 mm pitches
4
height
85 mm
Width
36 mm
Depth
69 mm
Net weight
220 g
Colour
White (RAL 9003)
[Ipe] Ground residual current
0.003 mA 0.6 mA
Connections - terminals
Tunnel type terminal (top or bottom) 4…16 mm² flexible Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Wire stripping length
14 mm
Tightening torque
3.5 N.m
IK degree of protection
IK03 conforming to IEC 62262
Relative humidity
5…95 %
Operating altitude
2000 m
Ambient air temperature for operation
-25…60 °C
Ambient air temperature for storage
-40…85 °C
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.2 cm
Package 1 Width
7.2 cm
Package 1 Length
9.2 cm
Package 1 Weight
248 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.5 cm
Package 2 Width
10 cm
Package 2 Length
27.8 cm
Package 2 Weight
1.561 kg
Unit Type of Package 3
S03
Number of Units in Package 3
54
Package 3 Height
30 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
14.552 kg
Warranty
18 months
Datasheet