LV847292

MTZ1 Drawout - Micrologic 6.0 X

Trade Price

£2,247.56

Per

1

Unit

EA

Pack Quantity

1

LV847292

Technical Specifications

Range

MasterPacT

Device short name

MicroLogic 6.0 X

Product or component type

Control unit

Device application

Equipment protection, monitoring and control

circuit breaker application

Distribution IEC standard

Range compatibility

MasterPact MTZ1 circuit breaker

Poles

4P 3P

Protected poles description

3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN

[Ue] rated operational voltage

690 V AC, +/- 10 %

Network type

AC

Network frequency

50/60 Hz

Trip unit technology

Electronic

Trip unit protection functions

LSIG

Protection type

Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51 Earth fault conforming to ANSI 51N

Trip unit rating

400 A 630 A 800 A 1000 A 1250 A 1600 A

Mounting mode

Drawout

Neutral protection setting

1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)

[Ir] long time pick-up adjustment range

0.4...1 x In adjustable in step of 1 A

Long time delay adjustment type

Adjustable in step of 0.5 s

[tr] long-time delay adjustment range

12.5…600 s at 1.5 x Ir 0.5…24 s at 6 x Ir 0.7…16.6 s at 7.2 x Ir

Thermal memory

Yes

[Isd] short-time pick-up adjustment range

1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app

Short-time delay adjustment type

Adjustable

[tsd] short-time delay adjustment range

0.1…0.4 s I²t=on 0…0.4 s I²t=off

instantaneous pick-up adjustment type Ii

Adjustable

[Ii] instantaneous pick-up adjustment range

2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off

[li mode] instantaneous delay adjustment range

0 ms in fast 20 ms in standard

ground-fault pick-up adjustment type

Adjustable

[Ig] ground-fault pick-up adjustment range

with In > 400 A 0.2...1 x In adjustable in step of 1 or 10 A with In <= 400 A 0.3...1 x In adjustable in step of 1 or 10 A Ig enable on/off

ground-fault time delay adjustment type

Adjustable

[tg] Ground-fault time delay adjustment range

0.1…0.4 s I²t=on 0…0.4 s I²t=off

Zone selective interlocking ZSI

With

Network and machine diagnosis type

System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state

Type of measurement

Power meter

Energy management

Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy

Metering type

Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage

Measurement voltage

208…828 V AC 50/60 Hz phase to phase 120…480 V AC 50/60 Hz phase to neutral

Frequency measurement range

40…70 Hz

Measurement accuracy

Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %

Accuracy class

Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)

Display type

LCD display - 128 x 96 pixels

Communication port protocol

Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer conforming to ISO 15963 USB peer to peer 115 kbauds

data recording

Alarm logs Maintenance logs Min/max of instantaneous values Time stamping Data logs Event logs

standards

EN/IEC 60092-202 EN/IEC 60947-2 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1

Mounting location

Indoor use only

Environmental characteristic

Wet location not approved for use conforming to IEC 61010-1

Electromagnetic compatibility

Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22

Overvoltage category

IV conforming to IEC 61010-1

Measurement category

Category IV conforming to IEC 61010-2-30

Pollution degree

3 conforming to IEC 60947-1

Ambient air temperature for operation

-25…70 °C (operating) -35 °C (for start-up of product)

Relative humidity

95 % at 55 °C conforming to IEC 60068-2-30

Operating altitude

<= 2000 m without derating <= 4000 m with operational voltage derating 600 V AC <= 5000 m with operational voltage derating 560 V AC

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

6.8 cm

Package 1 Width

8.0 cm

Package 1 Length

21.5 cm

Package 1 Weight

369.0 g

Warranty

18 months

Document Links

Catalogue page

Datasheet