516/2813B

16 Way Split Load Consumer Unit 100A Main Switch +8, 100A 30mA RCD +8

Trade Price

£319.81

Per

1

Unit

EACH

Pack Quantity

516/2813B

Information

Full metal enclosure. Plug in insulated busbar assembly. 8+8W Split load. 1x 100A 30mA type A RCCB.

Technical Specifications

Mounting method

Surface mounted (plaster)

Number of phases

1

Protection

Miniature- / earth leakage circuit breaker

Total number of groups

2

Number of poles main switch

2

Main switch rated current

100 A

Over voltage protection

No

Material housing

Steel

Degree of protection (IP)

IP2XC

Height

261 mm

Width

438 mm

Width in number of modular spacings

20

Depth

121 mm

Extension possible

No

With transparent cover

No

Lockable

Yes

Product Standard/s

BS EN 61439-3

Frequency

50 Hz

CE Conformity

Yes

WEEE Symbol

Yes

UKCA Conformity

Yes

Amperage

100 A

Operating Voltage

230 V

Type of Current

AC

Consumer Unit Type

Split load

Total final circuit modular ways

16

Busbar type

Plug in

Main switch rating

100 A

Main switch final circuit modular ways

8

RCD 1

100A 30mA type A

RCD 1 final circuit modular ways

8

Colour RAL

9010