1SFL427001R1311

AF116-30-11-13 100-250V50/60HZ-DC (AF116-30-11-13)

Trade Price

£474.92

Per

1

Unit

EA

Pack Quantity

1

1SFL427001R1311

Information

The AF116-30-11-13 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Technical Specifications

Minimum Order Quantity:

1 piece

Customs Tariff Number:

85364900

Product Net Width:

90 mm

Product Net Depth / Length:

126 mm

Product Net Height:

150 mm

Product Net Weight:

1.55 kg

Number of Main Contacts NO:

3

Number of Main Contacts NC:

0

Number of Auxiliary Contacts NO:

1

Number of Auxiliary Contacts NC:

1

Rated Operational Voltage:

Main Circuit 690 V

Rated Frequency (f):

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith):

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A

Rated Operational Current AC-1 (Ie):

(690 V) 40 °C 160 A(690 V) 60 °C 145 A(690 V) 70 °C 130 A

Rated Operational Current AC-3 (Ie):

(415 V) 55 °C 116 A(440 V) 55 °C 116 A(500 V) 55 °C 110 A(690 V) 55 °C 65 A(380 / 400 V) 55 °C 116 A(220 / 230 / 240 V) 55 °C 116

Rated Operational Current AC-3e (Ie):

(415 V) 60 °C 116 A(440 V) 60 °C 116 A(500 V) 60 °C 110 A(690 V) 60 °C 65 A(380 / 400 V) 60 °C 116 A(220 / 230 / 240 V) 60 °C 116 A

Rated Operational Power AC-3 (Pe):

(415 V) 55 kW(440 V) 75 kW(500 V) 75 kW(690 V) 55 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW

Rated Operational Power AC-3e (Pe):

(415 V) 55 kW(440 V) 75 kW(500 V) 75 kW(690 V) 55 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW

Rated Breaking Capacity AC-3:

8 x Ie AC-3

Rated Breaking Capacity AC-3e:

8.5 x Ie AC-3e

Rated Making Capacity AC-3:

10 x Ie AC-3

Rated Making Capacity AC-3e:

12 x Ie AC-3e

Short-Circuit Protective Devices:

gG Type Fuses 250 A

Rated Short-time Withstand Current Low Voltage (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A

Maximum Breaking Capacity:

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A

Maximum Electrical Switching Frequency:

(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour

Rated Operational Current DC-1 (Ie):

(110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A

Rated Operational Current DC-3 (Ie):

(110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A

Rated Operational Current DC-5 (Ie):

(110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A

Rated Insulation Voltage (Ui):

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):

Main Circuit 8 kV

Mechanical Durability:

5 million

Maximum Mechanical Switching Frequency:

300 cycles per hour

Coil Operating Limits:

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc):

50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V

Coil Consumption:

Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage DC 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage DC 135 W

Operate Time:

Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms

Connecting Capacity Main Circuit:

Flexible 2 x 10 ... 70 mm²Rigid Cu-Cable 2 x 10 ... 95 mm²

Connecting Capacity Auxiliary Circuit:

Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²

Degree of Protection:

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type:

Double Clamp

Maximum Operating Voltage UL/CSA:

Main Circuit 600 V

General Use Rating UL/CSA:

(600 V AC) 160 A

Horsepower Rating UL/CSA:

(200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 40 hp(440 ... 480 V AC) Three Phase 75 hp(550 ... 600 V AC) Three Phase 100 hp

Ambient Air Temperature:

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible:

Without Derating 3000 m

RoHS Status:

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

ABB EcoSolutions:

Yes

Circular Design Principles Recyclability Rate:

Design for Closing Resource Loops - Standard EN45555 - 87.8 %

Group Waste to Landfill Target:

Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility

Improved Resource Efficiency for Customers:

Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line

Sustainable Material Content:

Recycled Metal - 37 %

Package Level 1 Units:

box 1 piece

Package Level 1 Width:

207 mm

Package Level 1 Depth / Length:

216 mm

Package Level 1 Height:

150 mm

Package Level 1 Gross Weight:

1.75 kg

Package Level 1 EAN:

7320500476376

Object Classification Code:

Q

ETIM 4:

EC000066 - Magnet contactor, AC-switching

ETIM 5:

EC000066 - Magnet contactor, AC-switching

ETIM 6:

EC000066 - Power contactor, AC switching

ETIM 7:

EC000066 - Power contactor, AC switching

ETIM 8:

EC000066 - Power contactor, AC switching

eClass:

V11.0 : 27371003

UNSPSC:

39121529

IDEA Granular Category Code (IGCC):

4758 >> Iec Contactors

E-Number (Finland):

3706167

E-Number (Norway):

4117610

E-Number (Sweden):

3210068

Document Links