Trade Price
£29.19
Per
1
Unit
EA
Pack Quantity
1
The BC6-30-10 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Due to the low coil consumption, this device can be directly controlled by a PLC. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Minimum Order Quantity
1 piece
Customs Tariff Number
85365080
Product Net Width
52.5 mm
Product Net Height
57.5 mm
Product Net Depth / Length
46.7 mm
Product Net Weight
0.175 kg
Number of Poles
3
Mini Contactor Type
Interface Mini Contactor
Rated Operational Voltage
Auxiliary Circuit 690 V ACAuxiliary Circuit 250 V DCMain Circuit 690 V ACMain Circuit 220 V DC
Rated Frequency (f)
Control Circuit DCMain Circuit 60 HzMain Circuit 50 HzMain Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kVMain Circuit 6 kV
Rated Insulation Voltage (Ui)
690 Vacc. to UL/CSA 600 V
Number of Main Contacts NC
0
Number of Main Contacts NO
3
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 20 A(220 / 240 V) 55 °C 16 A(380 / 440 V) 40 °C 20 A(380 / 440 V) 55 °C 16 A(690 V) 40 °C 6 A(690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 2.2 kW(400 V) Three Phase 4 kW(500 V) Three Phase 4 kW(690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC
0
Number of Auxiliary Contacts NO
1
Rated Operational Current AC-15 (Ie)
(24 V) 4 A(120 V) 4 A(500 V) 2 A(220 / 240 V) 4 A(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)
(24 V) 2.5 A(110 V) 0.7 A(220 / 240 V) 0.4 A
Conventional Free-air Thermal Current (Ith)
Main Circuit 20 A
Rated Control Circuit Voltage (Uc)
24 V DC
Coil Operating Limits
(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ <= 55 °C)
Degree of Protection
Auxiliary Circuit Terminals IP20Control Circuit Terminals IP20Main Circuit Terminals IP20
Mechanical Durability
10000000 cycle
Minimum Switching Capacity
Auxiliary Circuit 17 VAuxiliary Circuit 5 mA
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-15) 600 cycles per hour(AC-3) 600 cycles per hour(DC-1) 600 cycles per hour(DC-13) 600 cycles per hour(DC-3) 600 cycles per hour
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²Flexible 1/2x 1 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²Flexible 1/2x 1 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 1 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²Flexible 1/2x 1 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²
Wire Stripping Length
Auxiliary Circuit 9 mmMain Circuit 9 mm
Tightening Torque
Auxiliary Circuit 0.8 ... 1.1 N·mControl Circuit 0.8 ... 1.1 N·mMain Circuit 0.8 ... 1.1 N·m
Recommended Screw Driver
M3Pozidriv 1
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W
Standards
IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1
Remarks
No CA6 or CAF6 mountable
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Full Load Amps Motor Use
(115 V AC) Single Phase 5.8 A(200 V AC) Three Phase 4.8 A(220 ... 240 V AC) Three Phase 6.8 A(230 V AC) Single Phase 4.9 A(440 ... 480 V AC) Three Phase 4.8 A(550 ... 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.25 Hp(200 V AC) Three Phase 1 Hp(220 ... 240 V AC) Three Phase 2 Hp(230 V AC) Single Phase 0.5 Hp(440 ... 480 V AC) Three Phase 3 Hp(550 ... 600 V AC) Three Phase 1 Hp
General Use Rating UL/CSA
(300 V AC) 12 A
Contact Rating UL/CSA
A600
Connecting Capacity Main Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Stranded 1/2x 22-10 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lbControl Circuit 7 in·lbMain Circuit 7 in·lb
Ambient Air Temperature
Operation -20 ... +55 °CStorage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
Resistance to Vibrations acc. to IEC 60068-2-6
5g / 5 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Package Level 1 Units
box 10 piece
Package Level 1 Width
115 mm
Package Level 1 Height
54 mm
Package Level 1 Depth / Length
280 mm
Package Level 1 Gross Weight
1.82 kg
Package Level 1 EAN
4013614414794
Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
E-Number (Finland)
3709133
E-Number (Sweden)
3210071
IDEA Granular Category Code (IGCC)
4763 >> Power contactor, DC switching